Signs Your Ductwork Is Costing You Comfort and Energy in North Bay
North Bay industrial and commercial facilities rely on two common types of equipment for comfort and air quality: packaged rooftop units and make-up air systems. They solve different problems. Choosing the wrong one, or expecting one to do the job of the other, leads to poor temperature control, high energy use, or negative pressure issues. A.R. Mechanical installs and services both and can recommend the right mix after reviewing your building and processes.
How rooftop units work
A packaged rooftop unit (RTU) combines heating and cooling in one cabinet that sits on the roof and connects to ductwork. It recirculates indoor air, conditions it, and supplies it back to the space. Many RTUs also bring in a limited amount of outdoor air for ventilation.
Rooftop units are typically the right choice when:
- The main need is heating and cooling occupied spaces such as offices, production floors, warehouses, or retail areas.
- The building already has ductwork designed for recirculating comfort air.
- Ventilation loads are moderate and can be met with the outdoor-air capability built into the RTU.
- You want a single packaged system that is relatively straightforward to service and replace.
A correctly sized RTU maintains temperature effectively. It is not designed to replace large volumes of air being exhausted by process equipment.
How make-up air systems work
A make-up air (MUA) unit brings in 100 percent outdoor air, conditions it, and supplies it to the building to replace air that is being exhausted. Common applications include facilities with large exhaust fans, paint booths, kitchens, welding areas, or any process that removes significant air from the space. Without adequate make-up air, the building goes negative, doors become hard to open, exhaust systems lose performance, and comfort suffers.
Make-up air systems are typically required when:
- Exhaust fans or process equipment remove large amounts of air.
- The building experiences negative pressure, whistling doors, or poor exhaust performance.
- Codes or processes demand high volumes of fresh outdoor air.
- You need to temper incoming air so it does not dump cold winter air or hot summer air directly into the space.
MUA units heat (and sometimes cool) the incoming outdoor air. They do not recirculate indoor air the way a standard rooftop unit does.
Side-by-side comparison
| Factor | Rooftop unit (RTU) | Make-up air system |
|---|---|---|
| Primary job | Heat and cool recirculated air | Replace exhausted air with conditioned outdoor air |
| Airflow | Mostly recirculated, some outdoor air | 100% outdoor air |
| Best for | Comfort in occupied zones | Buildings with high exhaust volumes |
| Duct connection | Supply and return ducts | Usually supply only |
| Negative pressure | Does not solve large exhaust deficits | Directly addresses negative pressure |
| Energy use | Lower when recirculating | Higher because all air is outdoor air |
| Common pairing | Often used alongside MUA | Often paired with RTUs for comfort |
How the two work together
Many facilities need both. Rooftop units handle temperature control in the main occupied areas. Make-up air units offset the air removed by exhaust fans so the building stays balanced and the RTUs are not fighting negative pressure or uncontrolled infiltration. When either system is undersized or poorly maintained, the other cannot fully compensate.
Which system A.R. Mechanical usually recommends
- Choose or replace rooftop units when the primary issue is heating and cooling comfort and exhaust volumes are modest.
- Add or replace make-up air when exhaust fans are strong, doors are hard to open, or processes require high outdoor-air volumes.
- Review both if the facility has comfort problems and ventilation or pressure problems at the same time.
- Size either system with a proper load and airflow calculation rather than simply matching existing equipment.
The right configuration depends on your exhaust rates, occupancy, process loads, and existing ductwork. A.R. Mechanical’s certified technicians assess the facility before recommending equipment.
A.R. Mechanical serves commercial and industrial clients across North Bay and the surrounding area with heating, cooling, and ventilation. The team of 11 certified technicians is based at 49 Lakeshore Drive. Call (705) 472-6117 to schedule an assessment and determine whether your facility needs rooftop units, make-up air, or both.